Make sure to overwrite the current macro programs. The WIPS programs or macro variables are corrupted. The probe stylus is not concentric to the spindle centerline (runout).Īdjust the probe stylus to eliminate runout. The probe does not give repeatable location results. To correct this issue calibrate the spindle probe.Īlarm 1106 or 1107 OMP40 Needs Calibration To correct this issue re-calibrate the spindle probe. The spindle probe tool offset does not match macro variable #10561. Settings in the work probe are not correct Replace defective tool and establish correct tool offset value. This alarm occurs if a tool is out of user defined tolerance. Occurs if the probe is already triggered before a move or triggered while positioning the probe or tool.Ĭlear faults and restart from safe position, check if chips are trapped around probe eyelids The surface of the part was found, when not expected. Settings in the work probe are not correct. Inputs are mixed, missing, or incorrectly formatted.Īlarm 1092 PROBE OPEN/UNEXPECTED SURFACE FOUND G43 or G44 is not active before the cycle is called.Įdit the program and start again from a safe position. Recommended protected positioning feed rate is 120 in/min. Insert the F code input and start again from a safe position. Clear the obstruction and start again from a safe position.